System Sensor 2WTA-B i3 Series Smoke Detector

  • Sale
  • $75.50
  • Regular price $107.79


**CALL FOR AVAILABILITY**

The i3 detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the i3 line, to minimize nuisance alarms. When the i3 is connected to the following, the 2-wire, i3 detectors are capable of generating a remote maintenance signal.

  • 2W-MOD Loop Test/Maintenance Module
  • i3 ready panel (MS-2 and MS-4) equipped with the i3 protocol

The remote maintenance signal indicates when the i3 required cleaning and it is indicated via an LED located at the module and/or the panel. To read the sensitivity of i3 detectors, the SENS-RDR is a wireless device that displays the sensitivity in terms of percent per foot obscuration.

The i3 Series provide wide angle, red and green LED indicators that allow you to instantly inspect the following detector conditions: normal standby / Alarm / Out-of-sensitivity / Freeze trouble condition.

When the i3 is connected to the 2W-MOD Loop Test/Maintenance Module or an i3 ready panel (i.e., MS-2 and MS-4) with the i3 protocol, the EZ Walk loop test feature is available on 2-wire i3 detectors. This feature verifies the initiating loop wiring by providing the LED status indication at each detector.

Features

  • Constructed of built-in remote maintenance signaling and a built-in test switch.
  • Provides drift compensation and smoothing algorithms.
  • Contains a Stop-Drop ‘N Lock attachment to the base.
  • Offers simplified sensitivity measurement.
  • Includes plug-in detector line - mounting base included.
  • Has a large wire entry port.
  • Installs with in-line terminals with SEMS screws.
  • Mounts to octagonal and single-gang backboxes, 4” (10.16 cm) square backboxes, or direct to ceiling.
  • Designed with a removable detector cover and chamber to simplify cleaning.
  • Equipped with a wide angle, dual color LED indication.
  • Uses loop testing via EZ Walk feature.

Specifications

Operating Voltage: 12/24 VDC (peak)
Standby Current: 2-wire: 50 ìA maximum average
Maximum Alarm Current: 2-wire: 130 mA limited by control panel
Operating Temperature Range: 32°F – 120°F (0°C – 49°C)
Operating Humidity Range: 0% to 95% RH non-condensing
Thermal Sensor: 135°F (57.2°C) fixed
Sensitivity: 2.5% /ft. nominal
Input Terminals: 14 – 22 AWG
Dimensions (including base): 5.3 inches (127 mm) diameter, 2.0 inches (51 mm) height
Weight: 6.3 oz. (178 grams)
Mounting: 3.5-inch (8.8 cm) octagonal backbox 4-inch (10.16 cm) octagonal backbox. Single-gang back box 4-inch (10.16 cm) square backbox with plaster ring. Direct mount to ceiling.)